1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
|
maxretry = 3
[rack]
driver = "usbhid-ups"
port = "auto"
vendorid = "0764"
productid = "0601"
product = "CP1500PFCRM2U"
serial = "BHWNS7000156"
vendor = "CPS"
bus = "001"
override.battery.charge.low = 50
override.battery.runtime.low = 600
# Network UPS Tools: example ups.conf
#
# --- SECURITY NOTE ---
#
# If you use snmp-ups and set a community string in here, you
# will have to secure this file to keep other users from obtaining
# that string. It needs to be readable by upsdrvctl and any drivers,
# and by upsd.
#
# ---
#
# This is where you configure all the UPSes that this system will be
# monitoring directly. These are usually attached to serial ports, but
# USB devices and SNMP devices are also supported.
#
# This file is used by upsdrvctl to start and stop your driver(s), and
# is also used by upsd to determine which drivers to monitor. The
# drivers themselves also read this file for configuration directives.
#
# The general form is:
#
# [upsname]
# driver = <drivername>
# port = <portname>
# < any other directives here >
#
# The section header ([upsname]) can be just about anything as long as
# it is a single word inside brackets. upsd uses this to uniquely
# identify a UPS on this system.
#
# If you have a UPS called snoopy, your section header would be "[snoopy]".
# On a system called "doghouse", the line in your upsmon.conf to monitor
# and manage it would look something like this:
#
# MONITOR snoopy@doghouse 1 upsmonuser mypassword primary
#
# It might look like this if monitoring in "secondary" mode (without any
# ability to directly manage the UPS) from a different system:
#
# MONITOR snoopy@doghouse 1 upsmonuser mypassword secondary
#
# Configuration directives
# ------------------------
#
# These directives are used by upsdrvctl only and should be specified outside
# of a driver definition:
#
# maxretry: OPTIONAL. Specify the number of attempts to start the driver(s),
# in case of failure, before giving up. A delay of 'retrydelay' is
# inserted between each attempt. Caution should be taken when using
# this option, since it can impact the time taken by your system to
# start.
#
# The built-in default is 1 attempt.
#
# retrydelay: OPTIONAL. Specify the delay between each restart attempt of the
# driver(s), as specified by 'maxretry'. Caution should be taken
# when using this option, since it can impact the time taken by your
# system to start.
#
# The default is 5 seconds.
#
# chroot: OPTIONAL. Used for securing. See man page for details.
#
# driverpath: OPTIONAL. Used for custom setups. See man page for details.
#
# nowait: OPTIONAL. Tell upsdrvctl to not wait at all for the driver(s)
# to execute the requested command. Fire and forget.
#
# pollinterval: OPTIONAL. The status of the UPS will be refreshed after a
# maximum delay which is controlled by this setting (default
# 2 seconds). This may be useful if the driver is creating too
# much of a load on your system or network.
# Note that some drivers also have an option called *pollfreq*
# which controls how frequently some of the less critical
# parameters are polled. See respective driver man pages.
#
# Set maxretry to 3 by default, this should mitigate race with slow devices:
# These directives can be set outside and inside a driver definition, with
# slightly different meanings per context:
#
# maxstartdelay: OPTIONAL. This can be set as a global variable
# above your first UPS definition and it can also be
# set in a UPS section. This value controls how long
# upsdrvctl will wait for the driver to finish starting.
# This keeps your system from getting stuck due to a
# broken driver or UPS.
# The default is 45 seconds.
#
# debug_min: OPTIONAL. Specify a minimum debug level for all driver daemons
# (when specified at global level), or for this driver daemon
# (when specified in a driver section), e.g. for troubleshooting
# a deployment. This does not directly impact the foreground or
# background running mode. If both the global and driver level
# `debug_min` are set, the driver-level setting takes precedence.
# Command-line option `-D` can only increase this verbosity level.
#
# user, group: OPTIONAL. Overrides the compiled-in (also global-section,
# when used in driver section) default unprivileged user/group
# name for NUT device driver. Impacts access rights used for
# the socket file access (group) and communication ports (user).
#
# synchronous: OPTIONAL. The driver work by default in asynchronous
# mode (like *no*) with fallback to synchronous if sending
# fails (i.e *synchronous=auto*). This means that all data
# are pushed by the driver on the communication socket to
# upsd (Unix socket on Unix, Named pipe on Windows) without
# waiting for these data to be actually consumed. With
# some HW, such as ePDUs, that can produce a lot of data,
# asynchronous mode may cause some congestion, resulting in
# the socket to be full, and the driver to appear as not
# connected. By enabling the 'synchronous' flag
# (value = 'yes'), the driver will wait for data to be
# consumed by upsd, prior to publishing more. This can be
# enabled either globally or per driver.
#
# The default is 'no' (i.e. asynchronous mode) for backward
# compatibility of the driver behavior.
#
# These directives are common to all drivers that support ups.conf:
#
# driver: REQUIRED. Specify the program to run to talk to this UPS.
# apcsmart, bestups, and sec are some examples.
#
# port: REQUIRED. The serial port where your UPS is connected.
# /dev/ttyS0 is usually the first port on Linux boxes, for example.
#
# sdorder: OPTIONAL. When you have multiple UPSes on your system, you
# usually need to turn them off in a certain order. upsdrvctl
# shuts down all the 0s, then the 1s, 2s, and so on. To exclude
# a UPS from the shutdown sequence, set this to -1.
#
# The default value for this parameter is 0.
#
# desc: optional, to keep a note of the UPS purpose, location, etc.
#
# nolock: optional, and not recommended for use in this file.
#
# If you put nolock in here, the driver will not lock the
# serial port every time it starts. This may allow other
# processes to seize the port if you start more than one by
# mistake.
#
# This is only intended to be used on systems where locking
# absolutely must be disabled for the software to work.
#
# ignorelb: OPTIONAL. Ignore low battery condition reported by device,
# and evaluate remaining battery charge or runtime instead.
# See man page for details.
#
# usb_set_altinterface(=num): OPTIONAL. Require that NUT calls this method
# to set the interface, even if 0 (default). Some devices require
# the call to initialize; others however can get stuck due to it -
# so it is not called by default. Yet others can be composite
# devices which use a non-zero interface to represent the UPS.
#
# default.<variable>: OPTIONAL. Set a default value for <variable> which is
# used in case the UPS doesn't provide a value, but which will be
# overwritten if a value is available from the UPS, e.g.:
# default.input.voltage.nominal = 230
# will report the nominal input voltage to be 230, unless the UPS
# eventually tells us differently.
#
# override.<variable>: OPTIONAL. Set a value for <value> that overrides
# (for NUT) any value that may be read from the UPS.
# Used for overriding values from the UPS that are clearly wrong
# (e.g. some devices report wrong values for battery voltage):
# override.battery.voltage.nominal = 12
# Use with caution! This will only change the appearance of the
# variable to the outside world (and NUT calculations), internally
# in the UPS the original value is used.
#
# Anything else is passed through to the hardware-specific part of
# the driver.
#
# Examples
# --------
#
# A simple example for a UPS called "powerpal" that uses the blazer_ser
# driver on /dev/ttyS0 is:
#
# [powerpal]
# driver = blazer_ser
# port = /dev/ttyS0
# desc = "Web server"
#
# If your UPS driver requires additional settings, you can specify them
# here. For example, if it supports a setting of "1234" for the
# variable "cable", it would look like this:
#
# [myups]
# driver = mydriver
# port = /dev/ttyS1
# cable = 1234
# desc = "Something descriptive"
#
# To find out if your driver supports any extra settings, start it with
# the -h option and/or read the driver's documentation.
|