diff --git a/nut/iron/ups.conf b/nut/iron/ups.conf
new file mode 100644
index 0000000..daddc52
--- /dev/null
+++ b/nut/iron/ups.conf
@@ -0,0 +1,215 @@
+maxretry = 3
+
+[rack]
+ driver = "usbhid-ups"
+ port = "auto"
+ vendorid = "0764"
+ productid = "0601"
+ product = "CP1500PFCRM2U"
+ serial = "BHWNS7000156"
+ vendor = "CPS"
+ bus = "001"
+ override.battery.charge.low = 50
+ override.battery.runtime.low = 600
+
+
+# Network UPS Tools: example ups.conf
+#
+# --- SECURITY NOTE ---
+#
+# If you use snmp-ups and set a community string in here, you
+# will have to secure this file to keep other users from obtaining
+# that string. It needs to be readable by upsdrvctl and any drivers,
+# and by upsd.
+#
+# ---
+#
+# This is where you configure all the UPSes that this system will be
+# monitoring directly. These are usually attached to serial ports, but
+# USB devices and SNMP devices are also supported.
+#
+# This file is used by upsdrvctl to start and stop your driver(s), and
+# is also used by upsd to determine which drivers to monitor. The
+# drivers themselves also read this file for configuration directives.
+#
+# The general form is:
+#
+# [upsname]
+# driver = <drivername>
+# port = <portname>
+# < any other directives here >
+#
+# The section header ([upsname]) can be just about anything as long as
+# it is a single word inside brackets. upsd uses this to uniquely
+# identify a UPS on this system.
+#
+# If you have a UPS called snoopy, your section header would be "[snoopy]".
+# On a system called "doghouse", the line in your upsmon.conf to monitor
+# and manage it would look something like this:
+#
+# MONITOR snoopy@doghouse 1 upsmonuser mypassword primary
+#
+# It might look like this if monitoring in "secondary" mode (without any
+# ability to directly manage the UPS) from a different system:
+#
+# MONITOR snoopy@doghouse 1 upsmonuser mypassword secondary
+#
+# Configuration directives
+# ------------------------
+#
+# These directives are used by upsdrvctl only and should be specified outside
+# of a driver definition:
+#
+# maxretry: OPTIONAL. Specify the number of attempts to start the driver(s),
+# in case of failure, before giving up. A delay of 'retrydelay' is
+# inserted between each attempt. Caution should be taken when using
+# this option, since it can impact the time taken by your system to
+# start.
+#
+# The built-in default is 1 attempt.
+#
+# retrydelay: OPTIONAL. Specify the delay between each restart attempt of the
+# driver(s), as specified by 'maxretry'. Caution should be taken
+# when using this option, since it can impact the time taken by your
+# system to start.
+#
+# The default is 5 seconds.
+#
+# chroot: OPTIONAL. Used for securing. See man page for details.
+#
+# driverpath: OPTIONAL. Used for custom setups. See man page for details.
+#
+# nowait: OPTIONAL. Tell upsdrvctl to not wait at all for the driver(s)
+# to execute the requested command. Fire and forget.
+#
+# pollinterval: OPTIONAL. The status of the UPS will be refreshed after a
+# maximum delay which is controlled by this setting (default
+# 2 seconds). This may be useful if the driver is creating too
+# much of a load on your system or network.
+# Note that some drivers also have an option called *pollfreq*
+# which controls how frequently some of the less critical
+# parameters are polled. See respective driver man pages.
+#
+
+# Set maxretry to 3 by default, this should mitigate race with slow devices:
+# These directives can be set outside and inside a driver definition, with
+# slightly different meanings per context:
+#
+# maxstartdelay: OPTIONAL. This can be set as a global variable
+# above your first UPS definition and it can also be
+# set in a UPS section. This value controls how long
+# upsdrvctl will wait for the driver to finish starting.
+# This keeps your system from getting stuck due to a
+# broken driver or UPS.
+# The default is 45 seconds.
+#
+# debug_min: OPTIONAL. Specify a minimum debug level for all driver daemons
+# (when specified at global level), or for this driver daemon
+# (when specified in a driver section), e.g. for troubleshooting
+# a deployment. This does not directly impact the foreground or
+# background running mode. If both the global and driver level
+# `debug_min` are set, the driver-level setting takes precedence.
+# Command-line option `-D` can only increase this verbosity level.
+#
+# user, group: OPTIONAL. Overrides the compiled-in (also global-section,
+# when used in driver section) default unprivileged user/group
+# name for NUT device driver. Impacts access rights used for
+# the socket file access (group) and communication ports (user).
+#
+# synchronous: OPTIONAL. The driver work by default in asynchronous
+# mode (like *no*) with fallback to synchronous if sending
+# fails (i.e *synchronous=auto*). This means that all data
+# are pushed by the driver on the communication socket to
+# upsd (Unix socket on Unix, Named pipe on Windows) without
+# waiting for these data to be actually consumed. With
+# some HW, such as ePDUs, that can produce a lot of data,
+# asynchronous mode may cause some congestion, resulting in
+# the socket to be full, and the driver to appear as not
+# connected. By enabling the 'synchronous' flag
+# (value = 'yes'), the driver will wait for data to be
+# consumed by upsd, prior to publishing more. This can be
+# enabled either globally or per driver.
+#
+# The default is 'no' (i.e. asynchronous mode) for backward
+# compatibility of the driver behavior.
+#
+
+# These directives are common to all drivers that support ups.conf:
+#
+# driver: REQUIRED. Specify the program to run to talk to this UPS.
+# apcsmart, bestups, and sec are some examples.
+#
+# port: REQUIRED. The serial port where your UPS is connected.
+# /dev/ttyS0 is usually the first port on Linux boxes, for example.
+#
+# sdorder: OPTIONAL. When you have multiple UPSes on your system, you
+# usually need to turn them off in a certain order. upsdrvctl
+# shuts down all the 0s, then the 1s, 2s, and so on. To exclude
+# a UPS from the shutdown sequence, set this to -1.
+#
+# The default value for this parameter is 0.
+#
+# desc: optional, to keep a note of the UPS purpose, location, etc.
+#
+# nolock: optional, and not recommended for use in this file.
+#
+# If you put nolock in here, the driver will not lock the
+# serial port every time it starts. This may allow other
+# processes to seize the port if you start more than one by
+# mistake.
+#
+# This is only intended to be used on systems where locking
+# absolutely must be disabled for the software to work.
+#
+# ignorelb: OPTIONAL. Ignore low battery condition reported by device,
+# and evaluate remaining battery charge or runtime instead.
+# See man page for details.
+#
+# usb_set_altinterface(=num): OPTIONAL. Require that NUT calls this method
+# to set the interface, even if 0 (default). Some devices require
+# the call to initialize; others however can get stuck due to it -
+# so it is not called by default. Yet others can be composite
+# devices which use a non-zero interface to represent the UPS.
+#
+# default.<variable>: OPTIONAL. Set a default value for <variable> which is
+# used in case the UPS doesn't provide a value, but which will be
+# overwritten if a value is available from the UPS, e.g.:
+# default.input.voltage.nominal = 230
+# will report the nominal input voltage to be 230, unless the UPS
+# eventually tells us differently.
+#
+# override.<variable>: OPTIONAL. Set a value for <value> that overrides
+# (for NUT) any value that may be read from the UPS.
+# Used for overriding values from the UPS that are clearly wrong
+# (e.g. some devices report wrong values for battery voltage):
+# override.battery.voltage.nominal = 12
+# Use with caution! This will only change the appearance of the
+# variable to the outside world (and NUT calculations), internally
+# in the UPS the original value is used.
+#
+# Anything else is passed through to the hardware-specific part of
+# the driver.
+#
+# Examples
+# --------
+#
+# A simple example for a UPS called "powerpal" that uses the blazer_ser
+# driver on /dev/ttyS0 is:
+#
+# [powerpal]
+# driver = blazer_ser
+# port = /dev/ttyS0
+# desc = "Web server"
+#
+# If your UPS driver requires additional settings, you can specify them
+# here. For example, if it supports a setting of "1234" for the
+# variable "cable", it would look like this:
+#
+# [myups]
+# driver = mydriver
+# port = /dev/ttyS1
+# cable = 1234
+# desc = "Something descriptive"
+#
+# To find out if your driver supports any extra settings, start it with
+# the -h option and/or read the driver's documentation.