diff options
| author | pants <niklasjo2004@gmail.com> | 2026-09-21 14:16:02 -0700 |
|---|---|---|
| committer | pants <niklasjo2004@gmail.com> | 2026-09-21 14:16:02 -0700 |
| commit | 40f81d08239763c2b5c05af63f17e3fd098d978d (patch) | |
| tree | b4475da076490a5fadc69904ad26bcf4ac46b9fc /nut/titanium/nut.conf | |
init
Diffstat (limited to 'nut/titanium/nut.conf')
| -rw-r--r-- | nut/titanium/nut.conf | 78 |
1 files changed, 78 insertions, 0 deletions
diff --git a/nut/titanium/nut.conf b/nut/titanium/nut.conf new file mode 100644 index 0000000..5da7122 --- /dev/null +++ b/nut/titanium/nut.conf @@ -0,0 +1,78 @@ +# Network UPS Tools: example nut.conf +# +# This file tries to standardize the various files being found in the field, +# like /etc/default/nut on Debian based systems, /etc/sysconfig/ups on RedHat +# based systems, ... Distribution's init script or service unit/method script +# should source this file to see which component(s) has to be started. +# Some scripts and units provided by NUT project itself may also look into +# this file for optional configuration about OS integration. +# +# IMPORTANT NOTES: +# This file is intended to be sourced by standard POSIX shell scripts +# (so there is no guaranteed `export VAR=VAL` syntax) and additionally +# by systemd on Linux (no guaranteed expansion of variables). +# You MUST NOT use spaces around the equal sign! +# Practical support for this file and its settings currently varies between +# various OS packages and NUT sample scripts, but should converge over time. +# +# See also: `man nut.conf` (usually in Manual pages Section 5, +# for Configuration files) +# +############################################################################## +# General section +############################################################################## +# The MODE determines which part of the NUT is to be started, and which +# configuration files must be modified. +# +# The values of MODE can be: +# - none: NUT is not configured, or use the Integrated Power Management, or use +# some external system to startup NUT components. So nothing is to be started +# by scripts or services bundled with NUT packages. +# - standalone: This mode address a local only configuration, with 1 UPS +# protecting the local system. This implies to start the 3 NUT layers (driver, +# upsd and upsmon) and the matching configuration files. This mode can also +# address UPS redundancy. +# - netserver: same as for the standalone configuration, but also need +# some more network access controls (firewall, tcp-wrappers) and possibly a +# specific LISTEN directive in upsd.conf. +# Since this MODE is opened to the network, a special care should be applied +# to security concerns. +# - netclient: this mode only requires upsmon (and tools it may be using, like +# upssched or custom scripts) to monitor a remote NUT server and possibly +# shut down this system (part of upsmon must run as root then). + +MODE=standalone + +# Uncomment this to allow starting the service even if `ups.conf` has no device +# sections configured at the moment. This environment variable overrides the +# built-in "false" flag in `upsd`, and an optional same-named default flag that +# can be set in `upsd.conf`. If you want a data server always running, even if +# it initially has nothing to serve (may be live-reloaded later, when devices +# become configured), this option is for you. +#ALLOW_NO_DEVICE=true +#export ALLOW_NO_DEVICE + +# The optional 'UPSD_OPTIONS' allow to set upsd specific command-line options. +# It is ignored when 'MODE' above indicates that no upsd should be running. +# It may be redundant in comparison to options which can be set in `upsd.conf`. +#UPSD_OPTIONS= + +# The optional 'UPSMON_OPTIONS' allow to set upsmon specific command-line options. +# It is ignored when 'MODE' above indicates that no upsmon should be running. +# It may be redundant in comparison to options which can be set in `upsmon.conf`. +#UPSMON_OPTIONS= + +# If the optional 'POWEROFF_WAIT' is configured (to a value that can be handled +# by `/bin/sleep` on the current system - typically an integer with the number +# of seconds for a delay, but not always limited to that syntax), and the current +# system which manages one or more UPS devices would not only command it to shut +# down, but also try to avoid the "Power race". Caveats emptor, see NUT FAQ and +# other docs for details. +#POWEROFF_WAIT=3600 + +# The optional 'POWEROFF_QUIET' setting controls if the NUT shutdown integration +# scripts or service units would emit messages about their activity (or lack +# thereof). By default they may be verbose, to aid post-mortem troubleshooting +# via logs or console captures. +# Set to `true` to avoid that trove of information, if you consider it noise. +#POWEROFF_QUIET=true |