#!/bin/sh # for UPS monitoring with NUT # #DATA_CMD="upsc ups@localhost" # on debian and freebsd, ups.realpower is not available. # calculate load in watts with load percent and max output instead. #MAX_OUTPUT=$($DATA_CMD | grep ups.realpower.nominal: | awk '{print $2}') #LOAD_VALUE=$($DATA_CMD | grep ups.load: | awk '{print $2}') #LOAD_PERCENT=$(echo "scale=2; $LOAD_VALUE/100" | bc) #POWER=$(echo "scale=0; $LOAD_PERCENT*$MAX_OUTPUT" | bc) # on void, ups.realpower is available! #POWER="$($DATA_CMD | grep ups.realpower: | awk '{print $2}') W" # "round" to integer. just removes decimal and whatevers after. not necessary with ups.realpower. #POWER="${POWER%.*} W" #CHARGE="$($DATA_CMD | grep battery.charge: | awk '{print $2}')%" #if [ "$CHARGE" = "100%" ]; then # echo $POWER #else # echo "$CHARGE $POWER" #fi # for battery monitoring everywhere else # # if power_now is present, just divide it to watts. # (from micro watts on thinkpads, perhaps something else on other platforms) if test -f /sys/class/power_supply/BAT*/power_now; then POWER=$(cat /sys/class/power_supply/BAT*/power_now) POWER="$(echo "scale=2; $POWER/1000000" | bc)W" else # if power_now is not present, calculate it: VOLTAGE=$(cat /sys/class/power_supply/BAT*/voltage_now) CURRENT=$(cat /sys/class/power_supply/BAT*/current_now) POWER="$(echo "scale=2; $VOLTAGE*$CURRENT/1000000000000" | bc)W" fi CHARGE="$(cat /sys/class/power_supply/BAT*/capacity)%" echo "$CHARGE $POWER"